Db D80 User Manual

Browse online or download User Manual for Receivers and Amplifiers Db D80. d&b D80 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Manual 1.9 en

DD80Manual 1.9 en

Page 2

Before starting up the device, please verify the shipment forcompleteness and proper condition of the items.If there is any sign of obvious damage to

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

4.1. OverviewConnectionsd&b audiotechnik GmbH[1] Mains connector socket.Refer to Þ Chapter 4.3.1. "Mainsconnection" on page 14 andÞ Cha

Page 4 - Contents

4.2. Rack mounting and coolingRack mountingThe D80 amplifier enclosure is designed to fit standard 19"equipment racks or cabinets.When specifyin

Page 5

Touring rack assembliesWhen using touring rack assemblies such as the d&b Z5330 D80Touring rack assembly or any other touring rack containing D80

Page 6 - 1. Introduction

4.3. Connections4.3.1. Mains connectionWARNING!Potential risk of electric shock.The device is a protective class 1 unit. A missing earth (ground)cont

Page 7 - D80 Rear view

NOTICE!Due to the high power capability of the device, only operate onedevice per phase conductor.Please also refer to Þ Chapter 12.1. "Power su

Page 8 - 2. Technical specifications

4.3.2. Audio INPUT and LINK connectorsAll signal input and link output connectors 1-4 are located on therear panel.These can be configured as four an

Page 9 - Dimensions and weight

4.3.3. Output connectorsWARNING!Potential risk of electric shock.The amplifier output pins can carry dangerous voltages.– Only use isolated loudspeak

Page 10 - 3. Scope of supply

4.3.4. ETHERNET (Dual Ethernet port)A Dual Ethernet port with a built-in 2-port Ethernet switch(10/100 Mbit/peer-to-peer) is provided enabling remote

Page 11 - 4. Startup

4.3.5. CAN (CAN-Bus)The device is equipped with a 2-wire serial remote control interfacecarrying the CAN-Bus signals to enable remote control with th

Page 12

SymbolsontheproductPleaserefertotheinformationinthemanual.WARNING!Dangerousvoltage!General informationD80 ManualVersion: 1.9 en, 06/2015, D2020.EN .01

Page 13

4.4. Controls and indicators4.4.1. Mains power switchThe on/off rotary switch [6] is located on the bottom right of thefront panel.OFFMains isolation

Page 14

4.4.3. Standby modeTo switch the device to Standby mode ... :1. Tap the «Power» button on the top right of the Home screen.A dialog appears allowing

Page 15

4.4.4. Mute functionsThe D80 provides two mute functions:– Individual mute buttons for each channel or pair of channelsÞ Channel mute,– and a master

Page 16

5.1. Operating conceptThe operating concept allows different methods of interaction andconfiguration.Touch screen in combination with the rotary enco

Page 17

5.2. Screen layout and conventionsThe screen layout is split into two main parts, the Header and theData sections.Header The Header (Headline) indica

Page 18

5.3.3. Input fieldsProperties:– The top left of the button shows the field name while thebottom right shows the value. The value can be edited.– Sele

Page 19

From the Home screen, the menu structure of the operatingsoftware is divided into two main axes, the Device setup and theChannel setup. The navigatio

Page 20

6.1. Header area - Device(from left to right):Power on indicatorYellow Indicates the start up phase of the power supply.Green Indicates that the unit

Page 21

D80 Channel strip block diagram (signal chain)The channel strip follows the actual signal chain from left to right:ISP/OVLIndicates the following sta

Page 22 - Channel muted

ISP/OSP/GR/OVLIndicates whether the DSP receives an input signal and whether theDSP output signal is present (provided the channel is not muted).Grey

Page 23 - 5. User interface

Explanation of graphical symbolsThe lightning symbol within a triangle is intended to alertthe user to the presence of uninsulated "dangerousvol

Page 24 - Basic screen layout

Due to the vast functional range and possible settings of the D80amplifier, this section is intended as a quick reference to provideyou with a system

Page 25

Speaker1. On the bottom left of the «Output» tab, select the «Speaker»navigation button to enter the Speaker setup subscreen.2. Choose the desired sp

Page 26 - 6. Home screen

Device setup access chartHierarchy level9. Device setup d&b D80 Manual 1.9 en32

Page 27

From the Home screen, selecting the Device view button opens theDevice setup screen with the «Input» tab being active.The Device setup screen follows

Page 28 - 7. Channel strip

9.2. InputSelecting the «Input» tab allows you to configure the Input modefor the input connector pairs 1/2 and 3/4 independently to accepteither ana

Page 29

Digital/DigitalNOTICE!When both input pairs are set to «Digital» and locking to the syncsource is not possible, none of the inputs will receive any a

Page 30

9.3. OutputSelecting the «Output» tab allows you to assign the appropriateOutput mode to a pair of amplifier output channels (AMP A/Band/or AMP C/D).

Page 31

9.3.1. Output modeNOTICE!Ensure that the connected loudspeaker type corresponds to theactual output configuration of the D80.Dual Channel mode (A/B,

Page 32 - 9. Device setup

Mix TOP/SUB mode (A/B MIX, C/D MIX)The Mix TOP/SUB mode allows d&b fullrange systems (passivesystems) and actively driven d&b subwoofers to b

Page 33

2-Way Active mode (2-WAY)The 2-Way Active mode is dedicated to d&b active systems.In 2-Way Active mode both amplifier channels of thecorrespondin

Page 34 - Input mode block diagram

1. Introduction... 61.1. Intended use...

Page 35

Mixed configurationsAs the output mode is assigned to a pair of amplifier channels(AMP A/B, AMP C/D) mixed configurations such as ...:– AMP A/B Þ Dua

Page 36 - Mixed configuration

9.4. RemoteSelecting the «Remote» tab allows you to assign remote settings forboth Ethernet and CAN remote control.Selecting the navigation field «IP

Page 37 - 2 x Dual Channel mode

9.4.2. Remote IDSelecting the «Remote ID» button allows the setting of the uniqueRemote identifier of the respective device in the format [nn].[nn].S

Page 38 - 2 x Mix TOP/SUB mode

9.5.1.1. DisplayThe «Display» tab provides the following display options.BacklightEnables the following optional settings:Off The display brightness

Page 39 - 2 x 2-Way Active mode

Home screen Switches to the Home screen.Levels Switches to the Levels screen.Edit passwordSelecting the «Edit password» option opens an input mask wh

Page 40 - Mixed configuration example

Note: All device preferences will be set to factory defaultsexcept for the network (CAN/Ethernet) and fixed devicesettings.If you execute this proced

Page 41

9.5.1.3.1. System resetSelecting «Clear all device settings to default» resets all devicesettings to factory defaults except for the network (CAN/Eth

Page 42

Tapping the «Hardware» button provides further hardware specificinformation.9.5.3. LevelsSelecting «Levels» opens the corresponding subscreen.The dat

Page 43

GR/OVL Indicates whether gain reduction (GR) of therespective channel is active or the respectivechannel is overloaded (OVL).Mains/SMPS Displays

Page 44

9.5.5. AmpPresetsd&b amplifiers provide AmpPresets which contain all importantuser settings of the entire device, such as input, output and chann

Page 45

9.5.6. Scope... 5010. Channel setup...

Page 46

Recall: Recalls the settings of a stored preset.Store: Stores the current amplifier settings to the selectedpreset memory.Clear: The selected preset

Page 47

Channel setup access chartHierarchy level10. Channel setup d&b D80 Manual 1.9 en 51

Page 48

Selecting a particular channel from the Home screen opens thecorresponding Channel setup screen with the respective Channeltab being active.The Chann

Page 49

10.2. Configuration switches - Filter_1, _2, _3The type of filters available depends on the selected loudspeakersetup.Depending on the type of filter

Page 50

EQ overviewThe upper part of the overview provides the overall frequencyresponse of all filters while «EQ 1» is displayed in red and «EQ 2»in yellow.

Page 51 - 10. Channel setup

Type Depending on the filter type used, 1 to 4bands may be required for each filter.The following table lists the available types,their correspondi

Page 52

10.5. DLY - DelayAn independent signal delay is available for each channel to allowdelay settings of up to 10000 ms/10 sec (3440 m/11286 ft).DLYOn/O

Page 53

10.7. System check/LM10.7.1. System checkSystem check is a powerful and convenient tool to check thecondition of a complete d&b sound reinforceme

Page 54

3. As a next step, execute a System calibration.ÞThe calibration process identifies the actual loadimpedances for each channel. The result will be st

Page 55

Load monitoring setupOn the «System check» screen, selecting «LM setup» opens thecorresponding subscreen.The «Load monitoring setup» menu provides al

Page 56

1.1. Intended useThe d&b D80 amplifier is designed for mobile applications andintended to be used with all current d&b loudspeakers. A LINEAR

Page 57

Speaker The bottom left of the «Speaker» input fielddisplays the version of the selected loudspeakersetup while the bottom right displays the actua

Page 58

10.8.1. ArrayProcessing (AP)Usually ArrayProcessing (AP) data are generated within theArrayCalc software and transferred to the amplifiers via the d&

Page 59

10.8.2. LoadMatchSelecting «LoadMatch» on the Speaker setup screen opens thecorresponding subscreen.ÞTo activate LoadMatch, tap the On/Off button on

Page 60

10.8.3. LINEAR setupIn addition to the loudspeaker specific setups, a LINEAR setup isalso available allowing the D80 to be used as a linear powerampl

Page 61

Level The level in dBu is adjustable from –57.5 dBto +6 dB in 0.5 dB steps.The level value corresponds to the level at thecontroller signal input.

Page 62

In addition, a Web Remote interface is integrated which providesdirect access to the user interface of a single amplifier using astandard web browser

Page 63

Refreshslow Default setting: Refresh rate is 30 seconds.This setting is recommended for larger amplifiernetworks in order to minimize network traffi

Page 64

1. Select the «Save» button at the bottom right corner of the webbrowser window.ÞA corresponding dialog will pop up providing you with adrop-down lis

Page 65 - 11. Web Remote interface

12.1. Power supplyThe device utilizes a switch mode power supply with active PowerFactor Correction (PFC) and automatic mains range selection.The pow

Page 66

12.1.4. Mains inrush current limiterThe Main Power Supply is started softly to limit inrush current. Upto two D80 may be powered up at the same time

Page 67 - Event.log to the local

The amplifier enables up to four input channels, which may be fouranalog inputs, two analog and two AES channels or four AESchannels. Each input chan

Page 68 - Nominal mains ranges

Maximum cable length for 5 % voltage drop at 3600 W mains power drawCable cross section 100 V 120 V 208 V 230 V1.3 mm2 - AWG 16Not permitted Not perm

Page 69

12.3. Cooling fansThree temperature and level controlled fans are incorporated forcooling the internal components, which allows greater coolingduring

Page 70

120 V AC / 60 Hz / 0.2 Ω Source impedanceMode/Signal LoadLinecurrentARMSPowerfactorInputpowerWOutputpower(sum.) WPowerlossWThermaldissipationBTU/hrTh

Page 71

13.1. ServiceCAUTION!Potential risk of explosion.The device incorporates a lithium battery which may cause dangerof explosion if not replaced correct

Page 72

13.2.2. Touch screen calibrationIndicationDue to mechanical impact or the aging process of the touchscreen, its calibration references may change.An

Page 73

14.1. EU declaration of conformity (CE symbol)This declaration applies to:d&b D80 Amplifier, Z2710manufactured by d&b audiotechnik GmbH.All p

Page 74

15.1. System check - ReferencesTypical impedance (Z) valuesThe following table indicates typical impedance values in ohms ford&b loudspeakers. Wi

Page 75

System Z LF Z HF Z MF/LF rearE0 12 11 -E12/12-D 7 13 -E12-SUB 8.5 - -E12X-SUB 7.5 - -E15X-SUB 7 - -E3 16 21 -E4 17 11 -E5 16 12 -E6 24 20 -E8 13 16 -

Page 76 - 15. Appendix

15.2. Max. number of cabinets operated in parallelThe following table indicates the maximum number of cabinetswhich can be operated in parallel by on

Page 77

System Failure mode Single cabinetdisconnectedHF section ofsingle cabinetSingle HF/MFdriverLF section ofsingle cabinetSingle LF driverE15X-SUB 3 - -

Page 78

Audio data (linear setting with subsonic filter)Maximum output power per channel (THD + N < 0.5%, all channelsdriven)CF = 6 dB @ 4/8 ohms 4 x 2600

Page 79

15.3. Error messagesThe following table lists possible error messages appearing on thedisplay.Id Error text Eventlog text Description Location Possib

Page 80

Id Error text Eventlog text Description Location Possible reasons38 SMPS overcurrent %dA SMPS Error: overcurrent(I-peak %3dA, avg%3dV, status %04X, e

Page 81

Id Error text Eventlog text Description Location Possible reasons80 Amp. ground fault Amp. ground fault (status%04X, err %04X,%5.1dV, %5.1dV)Ground f

Page 82

Id Error text Eventlog text Description Location Possible reasons121 CAN error CAN error %d (remoteflags %02X, dbCan flags%02X)CAN error Remote ID(Ex

Page 83

D2020.EN .01, 06/2015 © d&b audiotechnik GmbHwww.dbaudio.com

Page 84

Digital Signal ProcessingSystem start-up time 17 sec.Sampling rate 96 kHz / 27 Bit ADC / 24 Bit DACLatency analog input 0.3 msec.Latency digital inpu

Related models: 10D | 30D | D20 |

Comments to this Manuals

No comments